How to Select a Radiall high-current connector for a railway application: A practical guide for designers

Step 1. Do you really need a connector?
It is worth starting with the most basic distinction: not every application requires a connector. If frequent disconnection during operation or servicing is not expected and the connection will remain untouched throughout the entire service life, a terminal box may be an economically justified solution. The situation is different when access to the installation is required during inspections, overhauls, or repairs. In that case, the ability to disconnect a module quickly begins to have a direct impact on vehicle service time.
This is precisely why rolling stock manufacturers use connectors between the car body and bogie, at traction motors, inverters, rectifiers, braking resistors, or batteries. A repair that, with a permanent connection, would require removing cables, marking circuits, and recreating the connections can be made simpler and faster with a properly selected connector.
Step 2. Under what conditions will the connector operate?
Once it has been established that using a connector is justified, the next step should be to describe its actual operating conditions. Below are several factors that influence the selection of a specific component.
| Factor | Why is it important? |
|---|---|
| Operating current | Affects contact selection |
| Ambient temperature | May limit current carrying capacity |
| Vibration | Requires an appropriate locking mechanism |
| Moisture and corrosion | Require a high degree of sealing |
| Available space | Affects connector geometry |
In railway applications, a connector may operate near a traction motor, inverter, or on the roof of a vehicle exposed to direct sunlight. For this reason, parameter analysis cannot be limited to the rated current value. Thermal resistance, mechanical durability, and the ability to operate reliably over long periods in harsh environmental conditions are equally important. One of the key features of Radiall connectors is their ability to operate at high ambient temperatures while maintaining high current carrying capacity. In railway applications, it is worth analyzing not only the rated current, but also the derating characteristics of the specific contact.
Step 3. Where is the application located?
Not all locations in a vehicle impose the same requirements. For example, in an application located inside an electrical cabinet, the main limitation may be the available space. For a connection on the bogie, vibration, contamination, salt, moisture, and loads transferred by heavy cables become equally important. Below are several factors that should be considered depending on the installation location.
| Location | Main challenge |
|---|---|
| Car body–bogie connection | Vibration, mud, salt, moisture |
| Vehicle roof | UV, high temperature, precipitation |
| Between railcars | Relative movement and vibration |
| Traction motors | High current and temperature |
| Electrical cabinets | Limited space |
Step 4. Which Radiall Van System family should you choose?
The manufacturer focuses a significant part of its railway portfolio on demanding rooftop, undercarriage, and bogie applications, where mechanical and environmental resistance are critical. Once the application requirements are known, specific product families can be compared.
PWBS connector for car body–bogie connections and undercarriage installations
Radiall PWBS is the basic family of single-pole high-current connectors. It uses a bayonet mechanism that ensures fast and secure connection, while the circular design distributes clamping forces evenly and helps maintain a high degree of sealing. Connector keying is also available, eliminating the risk of incorrect connection. In practice, PWBS is particularly worth considering wherever the connector will operate in a harsh environment: at the car body–bogie interface, in undercarriage installations, traction systems, and locations exposed to intense vibration.
Radiall PWK connector for applications with limited installation space
The PWK series was designed for applications where installation space is limited. These connectors are made of plastic and are available in angled versions. Another advantage is their very good corrosion resistance and wide range of keying options. For this reason, the PWK series is worth considering, among other applications, in rooftop equipment, auxiliary systems, and HVAC installations, where installation geometry often determines how cables must be routed.
Radiall PWN connector for multi-circuit and modular power installations
In more complex power systems, an individual connector ceases to be an independent component and instead becomes part of a broader connection architecture. The PWN family develops this concept further by enabling more complex configurations and the routing of different circuits within a single system. This can make it an interesting solution for complex power modules and installations where different types of cables and power circuits are located side by side. Rather than viewing PWN solely as another connector series, it can therefore be treated as an element of a more flexible connection architecture.
Radiall CP for custom applications in rail vehicles
There are also projects in which the designer is not looking for an off-the-shelf connector with a specific part number, but rather needs a solution tailored to the architecture of a particular vehicle. In such cases, the CP family becomes an interesting option. Its advantage is the ability to customize the configuration more extensively to the requirements of the project, including the number of circuits, contact arrangement, geometry, and cable routing.
This approach is particularly important when designing new vehicle platforms, in projects with unusual space constraints, and wherever a standard connector configuration would force compromises in the vehicle design.
Not all answers can be found in the datasheet
Suppose that after analyzing the documentation, you have selected a PWK-family connector with a rated current of 600 A. This is a good starting point, but before approving the component, further questions may arise:
- Does 600 A apply to continuous operation?
- At what ambient temperature was this value specified?
- For what conductor cross-section?
- How does the permissible load change at 60 or 70°C?
- Does the manufacturer have experience with a similar installation location or similar operating conditions?
Some of these questions can be answered by the technical documentation. Others require direct contact with the manufacturer. In such a situation, a Soyter Components advisor can help verify the assumptions with Radiall Van System, obtain additional technical information, or check whether the manufacturer has test results, application data, or experience from similar projects.
How can Soyter support the designer?
We do not know your application as well as the team designing it. However, we can help when the analysis reaches the point where catalogue documentation is no longer sufficient. If you have already selected a solution and want to confirm a specific operating point, verify an unusual configuration, or obtain additional information about a particular Radiall series, we can direct the question to the appropriate people at the manufacturer.
Depending on the project, this may include attempting to obtain additional technical data, confirmation of specific operating conditions, information about available tests, or examples of similar applications, to the extent that the manufacturer is able to provide such information.
If you are considering Radiall connectors and have a question that is not answered in the documentation, contact Soyter. We will help you check what additional data or application experience is available for your project.